- Contact Person : Mr. Choi William
- Company Name : Anhui In-Sky General Trading Co., Ltd.
- Tel : 86-551-5336412
- Fax : 86-551-5336413
- Address : Anhui,Hefei,Shang-la Business Center, Hi-tech Zone, Hefei
- Country/Region : China
NEW 96V Solar charge controller 96V
No .1 General Description
The solar charge controller is the intelligent power with integration of controlling . It can store electrical power generated by the solar panels into the storage battery.
The controller not only has perfect appearance, LCD display and convenient operation, but also has over-charge protection, over-voltage protection, over-hot protection, under-voltage protection, pole-confusion protection for storage battery and automatic dump-load function. The controller is adopted the constant voltage charging mode-PWM, and it has high reliable and safe operation, high efficiency, long service life functions. What’s more, it adopts the American origin Micro-controller as a control core component with reliable. And the power parts of an apparatus adopt the import component, too.
No .2 Design characteristic.
1 PWM mode off-overload.
2 high Reliability.
3 LCD display the battery voltage and charge current.
4. LED of “system” is indicate device working status; LED of “battery” is indicate battery capacity whether be normal.
5. digital intelligent control.
No. 3 Functions
1. Charging and control.
2. Automatic regulate voltage.
3. Over-voltage protection.
4. Low-voltage protection.
5. short circuit protection
6. Battery reverse connection protection
No. 5 Technology Parameter
Model no. | IS-96-50A | IS-96-100A | IS-96-150A | IS-96-200A |
Max PV power | 5KW | 10KW | 15KW | 20KW |
PV array Input Control Line | 1 | 2/4 | 2/4 | 4 |
Max. current of each PV array line | ≤75A | ≤75A/50A | ≤120A/75A | ≤75A |
Rated current of each PV array | 50A | 50A/25A | 75A/37.5A | 50A |
Battery overcharge voltage (out of factory default voltage) | 116V | |||
Overcharge recovery voltage (out of factory default overcharge voltage) | 110V | |||
Over discharge voltage (out of factory default Over discharge voltage) | 86V | |||
over-discharge recovery voltage (out of factory default Over discharge voltage) | 92V | |||
Free-load current | ≤100mA | |||
Temperature Compensation (optional) | 4mV/°C/2V ,–35°C--+80°C ,precision: ±1°C | |||
operating ambient temperature | -20~+50°C/35~85%RH( but free from condensation ) | |||
Working height above sea level (m) | ≤5000(according to GB/T3859.2 derating use when sea level above 1000m) | |||
protection type | reverse current protection at night, Sollar cell reverse connection protection, battery over-charge and over discharge protection, battery anti-reverse connection | |||
level of protection | IP20 | |||
Dimension (L * W * H) | 420mm X 200mm X 160mm | |||
Net weight | 8.5KG |